A retained helper set electron_executable_included because the rank marks
every .exe or extensionless sibling of resources/app.asar. With more than four
siblings, or an inventory that stopped early, safe fuses on a helper reported
not_observed while the host went unread. Rank stays a sampling hint. The check
now settles only on an executable named as the host, or when inventory was
complete and every executable that could be the host was sampled.
A Bun sourcemap region is named .bunmap, so its role was lost and a complete
audit reported no source maps. Carry the region role from the reader's metadata
into the member view, in the expanded and unexpanded paths, and treat it as a
JavaScript map so an unparsable region stays unresolved, not a debug companion.
An HTML member was scanned as text but its inline scripts were never checked
for source maps. The HTML owner now returns each body, the reader examines it
like a script file, and bodies past the owner's limit count as skipped.
The fuse check counted sampled-out images as possibly unread but not native
images inside a package. A complete directory scan with a safe-fuse image on
disk, no ASAR hint, and an unopened packaged image reported the four Electron
checks as not_observed, although the Electron executable could be that image.
The fuse check, the Go and Rust checks, and the Electron rule-out each decided
this for themselves and had drifted apart. Move the decision to one domain
predicate, nativeImagesMayBeUnread, and use it in all three. A hinted
executable that was read still settles the check.
A desktop, fuse, Go or Rust failure became a string on that check, so an
error with unfinished cleanup lost its resources and live bindings while the
audit reported success, and the MCP handler does not close the service after
each request.
Treat unfinished cleanup like cancellation: stop the remaining owners and
return the error with the partial audit. When the owner attached its own
partial, keep the error and replace the partial, so cleanup stays attributed.
The applicability check only looked at the "native images" omission. An
Electron executable inside a compressed .NET or PyInstaller member is recorded
under "packaged native images", so a directory whose on-disk hosts had no fuse
sentinel read as not Electron and all four fuse checks as not applicable.
Treat that omission as an unread image too.
A directory inventory that stops at an acquisition limit never reports
the images it did not reach, so the native image sample has no omission
and safe fuses on an included helper settled to not_observed even though
scan coverage was unknown.
Treat unknown coverage like a truncated sample until the Electron
executable is accounted for. A selected native file is that executable,
so it keeps its decided fuse result.
GO_FLAG_PATH accepted dot-relative roots only with a forward slash, so
`-I..\sdk\include` and `-I.\sdk` produced no path and go.build_paths came
back not_observed. Accept either separator after the dots.
The CLI acceptance test now expects unknown for electron.run_as_node on a
directory with no native images, matching the service.
The desktop owner names Electron only from an ASAR layout, so an asar: false
build has no candidate. A complete scan with no candidate was reported as
not_electron, which outranks unresolved and safe fuse outcomes and hid them
as not_applicable.
Leave the family unknown unless the fuse holder rules Electron out: an app
bundle with no Electron Framework, or a directory with complete coverage
whose native images were all read and hold no sentinel. A directory with no
native image is not proof, so its fuse checks now report unknown.
A flag such as -I\\buildhost\sdk\include matched none of the path roots
in GO_FLAG_PATH, so a network path that was the only one in complete
build info left go.build_paths at not_observed. Accept \\host\share
roots alongside the slash-rooted, dot-relative and drive-letter forms.
Reopen package members by their source spelling and keep caller path
traversal in directory reads. Parse quoted and attached Go build flags, bind a
native image fuse read to its own digest, and keep reader resources and the
audit's partial report when cleanup or cancellation combine failures.
Probe files with unrecognized names as text, keep undecided fuse slices
unknown, forward opaque container coverage, read paths from Go build flags,
and compare inventoried digests before accepting owner facts.
Keep typed cleanup failures and attach the partial report when a later owner
is cancelled. Pin the verifier's @electron/fuses version and move the tests
to the named contract family.
Adds `audit_release_exposure` and `rea audit-release-exposure` to report
source maps, Electron fuse implications, extractable payloads, debug
information, build metadata, and credential markers. Checks carry stable
IDs, observations, statuses, and fixed remediation, while incomplete and
unassessed checks remain visible without implying a security verdict.
Credential findings include only rule IDs and locations. The CLI
supports `--fail_on` severity thresholds and exits 3 when an exposed
check meets the threshold.