Files
reverse-engineering-anything/src/application/javascript/ElectronObservationService.ts
T
morluto ecf6ac9f8d fix(electron): admit provider reports and bind selected inputs (#10041)
* fix(electron): admit runtime observations before publishing evidence

* fix(electron): retain passive observation source JSON
2026-11-11 17:15:54 +08:00

192 lines
6.3 KiB
TypeScript

import type { ExecutionOptions } from "../AnalysisProvider.js";
import type { ElectronObservationPort } from "./ElectronObservationPort.js";
import type { Evidence } from "../../domain/evidence.js";
import type {
ElectronPageInspection,
InspectElectronPageInput,
ListElectronTargetsInput,
} from "../../domain/javascript/electronObservation.js";
import {
AnalysisCancelledError,
AnalysisCapabilityUnavailableError,
AnalysisOutputError,
} from "../../domain/analysisErrorCore.js";
import type { AnalysisError } from "../../domain/analysisErrorBase.js";
import { err, ok, type Result } from "../../domain/result.js";
import { createElectronEvidence } from "./ElectronEvidence.js";
import { jsonObjectSchema, jsonValueSchema } from "../../domain/jsonValue.js";
import {
electronPageInspectionSchema,
electronTargetListSchema,
} from "../../domain/javascript/electronObservation.js";
import {
completeProviderEvidence,
keepIncompleteObservation,
} from "../ProviderOperationExecution.js";
/** List local file pages exposed by the explicitly selected endpoint. */
export const listElectronTargets = async (
provider: ElectronObservationPort | undefined,
input: ListElectronTargetsInput,
options: ExecutionOptions = {},
): Promise<Result<Evidence, AnalysisError>> => {
const ready = requireProvider(provider, "list_electron_targets");
if (!ready.ok) return ready;
if (options.signal?.aborted)
return err(
new AnalysisCancelledError("list_electron_targets", {
cause: options.signal.reason,
}),
);
const result = await ready.value.listTargets(input, options);
if (!result.ok) return result;
const json = jsonValueSchema.safeParse(result.value);
if (!json.success)
return err(
new AnalysisOutputError(
"list_electron_targets",
"Electron provider returned non-JSON target data.",
{ cause: json.error },
),
);
const report = electronTargetListSchema.safeParse(json.data);
if (!report.success)
return err(
new AnalysisOutputError(
"list_electron_targets",
"Electron provider returned a malformed target list.",
{ cause: report.error },
),
);
return completeProviderEvidence(
createElectronEvidence(
"list_electron_targets",
input,
{ source: json.data, facts: report.data },
ready.value.identity(),
),
options.signal,
);
};
/** Inspect one local file page from the explicitly selected endpoint. */
export const inspectElectronPage = async (
provider: ElectronObservationPort | undefined,
input: InspectElectronPageInput,
options: ExecutionOptions = {},
): Promise<Result<Evidence, AnalysisError>> => {
const ready = requireProvider(provider, "inspect_electron_page");
if (!ready.ok) return ready;
if (options.signal?.aborted)
return err(
new AnalysisCancelledError("inspect_electron_page", {
cause: options.signal.reason,
}),
);
const result = await ready.value.inspectPage(input, options);
if (!result.ok) {
const partial = jsonObjectSchema.safeParse(result.error.partialObservation);
if (partial.success && partial.data.kind === "electron-page-observation") {
const report = electronPageInspectionSchema.safeParse(
partial.data.inspection,
);
if (report.success) {
const mismatch = pageSelectionFailure(input, report.data);
if (mismatch !== undefined) {
result.error.retainSecondaryFailure(mismatch);
return err(
keepIncompleteObservation(
result.error,
"inspect_electron_page",
"Electron provider retained a non-JSON incomplete observation.",
),
);
}
const inspection = {
...report.data,
limitations: [
...report.data.limitations,
partial.data.cleanup === "transport-closed"
? "REA closed its CDP transport; this does not imply target shutdown."
: "CDP transport cleanup remains incomplete.",
],
} satisfies ElectronPageInspection;
result.error.partialObservation = createElectronEvidence(
"inspect_electron_page",
input,
{
source: jsonValueSchema.parse(partial.data.inspection),
facts: inspection,
},
ready.value.identity(),
);
return result;
}
}
return err(
keepIncompleteObservation(
result.error,
"inspect_electron_page",
"Electron provider retained a non-JSON incomplete observation.",
),
);
}
const json = jsonValueSchema.safeParse(result.value);
if (!json.success)
return err(
new AnalysisOutputError(
"inspect_electron_page",
"Electron provider returned non-JSON page data.",
{ cause: json.error },
),
);
const report = electronPageInspectionSchema.safeParse(json.data);
if (!report.success)
return err(
new AnalysisOutputError(
"inspect_electron_page",
"Electron provider returned a malformed page inspection.",
{ cause: report.error },
),
);
const mismatch = pageSelectionFailure(input, report.data);
if (mismatch !== undefined)
return err(mismatch.retainPartialObservation(report.data));
return completeProviderEvidence(
createElectronEvidence(
"inspect_electron_page",
input,
{ source: json.data, facts: report.data },
ready.value.identity(),
),
options.signal,
);
};
/** Retained facts must describe the page and window the caller selected. */
const pageSelectionFailure = (
input: InspectElectronPageInput,
report: ElectronPageInspection,
): AnalysisOutputError | undefined =>
report.target.target_id !== input.target_id ||
report.capture_window.observation_ms !== input.observation_ms
? new AnalysisOutputError(
"inspect_electron_page",
"Electron provider changed the selected page or observation window.",
)
: undefined;
const requireProvider = (
provider: ElectronObservationPort | undefined,
operation: "list_electron_targets" | "inspect_electron_page",
): Result<ElectronObservationPort, AnalysisError> =>
provider === undefined
? err(
new AnalysisCapabilityUnavailableError(
"rea-cdp-electron",
operation,
"Electron observation provider is not configured",
),
)
: ok(provider);