The reconnect probe closed its client and then connected again while the
bridge waited 0.2 s for the next accept. A probe stalled past that window
saw the listener closed (ConnectionRefusedError on main run 44855978833,
FileNotFoundError with an injected stall). Queue the successor connection
and its first request before ending the previous one, as the probe
already does for the first client, so neither the reconnect nor the
unauthenticated-idle budget depends on probe scheduling. A rejected
connection keeps its idle budget, so its successor is queued before the
probe reads the rejection.
Co-authored-by: gensokyo-dev <gensokyo-dev@users.noreply.github.com>
Co-authored-by: gensokyo-dev <342580529+gensokyo-dev@users.noreply.github.com>
* perf(mcp): index tool contracts, skip unadvertised projection, parallelize status probes, and stream tool result sizing
* fix(mcp): await readiness before session status and defer omission worklist
* perf(il2cpp): fix 8x yields and hoist opcode checks before BigInt math in executable scans
* test(il2cpp): type codegen module fixtures without as-never casts
* fix(website): verify markdown fragments from parsed headings
* fix(website): derive image heading fragments from parsed alt text
* fix(website): exclude YAML front matter from Markdown paths and anchors
---------
Co-authored-by: morluto <76467478+morluto@users.noreply.github.com>
With REA_MCP_TOOL_CATALOG_PROFILE=hot-cold, discover_tools is listed in
tools/list, yet an exact-name request that named it failed with "Unknown
or excluded tool names. No tools were loaded." Exact names load
atomically, so a batch such as ["inspect_sqlite_database",
"discover_tools"] also left the valid cold tool unloaded.
The catalog validated names against the domain registrations it was
built from, and the server registered the adapter only after building
it. The server now registers discover_tools first and passes that
registration to ProgressiveToolCatalog. Exact-name lookup, the returned
entries and both counts read one inventory that includes the adapter,
which replaces the two "+ 1" adjustments. Search and reset still cover
only domain tools, so a query never spends a page slot on the adapter
and reset never hides it. Unknown or excluded names are still rejected
before anything loads.
Signed-off-by: Deepak Jain <deepujain@gmail.com>
* fix(pwntools): release each PLT emulator so CET binaries keep their PLT map
pwntools 4.15.0 emulates each PLT section in a new Unicorn instance with
a 1 GiB virtual map, and hook closures keep each instance alive until
cyclic GC. Under the default 3 GiB address-space limit the third section
of a CET x86-64 image failed upstream's 1 GiB probe, so linkage.plt was
truncated with only a stderr warning (/usr/bin/ls: 4 of 108 entries).
Wrap upstream's emulate_plt_instructions for the PLT pass so each
section's emulator is collected before the next, restoring it in
finally. Peak PLT address space drops from about 3.2 GiB to 1.1 GiB.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
* test(pwntools): make the CET verifier deterministic and supervised
---------
Co-authored-by: aadheel <250292080+aadheel@users.noreply.github.com>
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
Co-authored-by: morluto <76467478+morluto@users.noreply.github.com>